 40W Single Output Industrial DIN Rail Power Supply
Features :
Universal AC input/Full range
MDR-40
series
Protections: Short circuit / Overload / Over voltage Cooling by free air convection Can be installed on DIN rail TS-35/7.5 or 15 NEC class 2 / LPS compliant (12V,24V,48V only) LED indicator for power on DC OK relay contact No load power consumption<0.75W 100% full load burn-in test 3 years warranty
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE FUNCTION DC OK SIGNAL WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE MDR-40-5 5V 6A 0 ~ 6A 30W 5 ~ 6V 2.0% 1.0% 1.0%
Note.5 500ms, 30ms/230VAC
MDR-40-12 12V 3.33A 0 ~ 3.33A 40W 120mVp-p 12 ~ 15V 1.0% 1.0% 1.0% 500ms, 30ms/115VAC at full load 20ms/115VAC at full load 120 ~ 370VDC 86%
MDR-40-24 24V 1.7A 0 ~ 1.7A 40.8W 150mVp-p 24 ~ 30V 1.0% 1.0% 1.0%
MDR-40-48 48V 0.83A 0 ~ 0.83A 39.8W 200mVp-p 48 ~ 56V 1.0% 1.0% 1.0%
RIPPLE & NOISE (max.) Note.2 80mVp-p
50ms/230VAC 85 ~ 264VAC 47 ~ 63Hz 78%
88%
88%
1.1A/115VAC 0.7A/230VAC COLD START 30A/115VAC 60A/230VAC <1mA / 240VAC 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6.25 ~ 7.25V 15.6 ~ 18V 31.2 ~ 36V 57.6 ~ 64.8V Protection type : Shut down o/p voltage, re-power on to recover Relay contact rating(max.): 30V/1A resistive -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.03%/ (0 ~ 50 Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6 UL508, UL60950-1, TUV EN60950-1 approved, NEC class 2 / LPS compliant (12V,24V,48V only)
SAFETY & EMC
(Note 4)
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:>100M Ohms/500VDC 25 70%RH ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B Compliance to EN61000-3-2,-3 HARMONIC CURRENT EMS IMMUNITY MTBF Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A 301.7K hrs min. MIL-HDBK-217F (25 40*90*100mm (W*H*D) 0.3Kg; 42pcs/13.6Kg/0.82CUFT )
OTHERS
NOTE
DIMENSION PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:MDR-40-SPEC 2008-03-10
40W Single Output Industrial DIN Rail Power Supply
Mechanical Specification
35
40 55555
MDR-40
Case No.962A
100
series
Unit:mm
+V +V -V -V DC OK DC OK
+
90
+V ADJ
N
L
7.5 7.5
Install DIN rail TS35/7.5 or TS35/15
Block Diagram
fosc : 60KHz
DC OK
I/P
EMI FILTER
RECTIFIERS & FILTER
POWER SWITCHING
RECTIFIERS & FILTER O.C.P. DETECTION CIRCUIT
+V -V
O.L.P.
CONTROL O.V.P.
DC OK Relay Contact
Contact Close Contact Open When the output voltage reaches the adjusted output voltage. When the output voltage drop below 90% output voltage.
Contact Ratings (max.) 30V/1A resistive load
Derating Curve
Output Derating VS Input Voltage
Ta=25
100
100 90
80
80 70
60
LOAD (%)
LOAD (%)
0 10 20 30 45 55 60 70 (VERTICAL)
40
60 50 40
20
-20
85
95
100
115
120
140
160
180
200
220
240
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (VAC) 60Hz
File Name:MDR-40-SPEC 2008-03-10


▲Up To Search▲   

 
Price & Availability of MDR-40-48

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X